HC6DW miniBOOSTER

HC6DW versions: 14 different intensification factors

PIN: Inlet pressure 20-207 bar

PH: 800 bar maximum (outlet pressure)

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PReturn) I (intensification)

Mounting: Inline tube

Accessories: Pilot-operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

 

Description

The HC6DW is a high flow dual-acting stainless steel 316 L unit which is capable of delivering up to 33.3 l/min flow on the high-pressure end. Like other miniBOOSTER models, the HC6DW raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC6DW is a compact unit weighing 34.8 kg.

Flow rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

1.5

33.3

50.0

1.8

27.5

50.0

2.0

25.0

50.0

2.2

22.5

50.0

2.5

20.0

50.0

3.0

16.5

50.0

3.3

15.0

50.0

4.0

12.5

50.0

4.9

10.0

50.0

6.3

8.0

50.0

8.2

6.0

50.0

11.1

4.5

50.0

13.2

3.5

50.0

16.0

3.0

50.0

Dimensions

6DW-122-07

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves 2x KV1, 2x KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump units OP1 and OP2 by turns. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP1 and OP2 units will automatically operate to maintain the end pressure. It is possible to change the high-pressure connection H to the opposite end of the booster.

Function diagram

0-146-02

Connection types

Connection

IN / R

1

1/2" BSP

Max. tightening torque BSP

IN / R

1/2" BSP

  with stainless steel washer

13.0 da/Nm

High-pressure adapters

  Ordering Code

Male connection 1

Female connection 2

Tightening torque

 6DW-816

M30 x 1.5

1/2" BSP

250 Nm

 6DW-817

M30 x 1.5

13/16-16 UNF

250 Nm

 6DW-815

M30 x 1.5

Plug

250 Nm

Fluids and materials

Please see General specifications

Dynamic seals

Code

Seal material

Outlet pressure

H

H-PUR

Max 800 bar HP

P

PEEK

Max 800 bar HP

E

EPDM

Max 500 bar HP

Ordering an HC6DW

HC6DW-……….....: with Bypass Valve (BPV) without Sequence Valve & Pressure Reducing Valve

HC6DWA-………..: with Bypass Valve (BPV) with Sequence Valve & Pressure Reducing Valve

HC6DWB-………..: without Bypass Valve (BPV) without Sequence Valve & Pressure Reducing Valve

Ordering example of an HC6DW with i = 4.0, DV incorporated ,BSP connections and H-PUR dynamic seals:
 HC6DW - 4.0 - B - 1H for media < 5 cSt (mm2/s) tested in water and mounted with H-PUR dynamic seals
 HC6DW - 4.0 - B - 1SH for media > 5 cSt (mm2/s) tested in hydraulic oil and mounted with H-PUR dynamic seals

Model

Intensification, i

Dump valve

Connections

Dynamic seals

HC6DW

-

your selection...

-

your selection...

-

your selection...

-

your selection...

see flow rate table 

A = (no) / A model 

1

H

B = (yes) / B model

P

E

 

Subscribe to our Newsletter





Get our quarterly newsletter in your inbox. Your name and email address are safe with us! We will not share your contact information with anyone outside the miniBOOSTER Company.

Iso 9001

miniBOOSTER Hydraulics A/S

Fynsgade 3

DK - 6400 Sønderborg

Denmark